TR、TRC、TRZ 型三环吃瓜91 的热功率Pt
规格  | 80  | 90  | 105  | 125  | 145  | 175  | 215  | 255  | 300  | 350  | 400  | 
减速器热功率Pt  | |||||||||||
SH TR型  | 1.57  | 1.99  | 2.71  | 3.84  | 5.16  | 7.52  | 11.4  | 16.0  | 22.1  | 30.0  | 39.3  | 
SHC TRC型  | 3.02  | 4.06  | 5.92  | 8.93  | 12.6  | 17.4  | 23.7  | 30.9  | |||
2.46  | 3.31  | 4.82  | 7.28  | 10.2  | 14.2  | 19.3  | 25.2  | ||||
SHZ TRZ型  | 2.70  | 3.63  | 5.29  | 7.98  | 11.2  | 15.5  | 21.2  | 27.6  | |||
2.44  | 3.28  | 4.78  | 7.22  | 10.1  | 14.1  | 19.1  | 25.0  | ||||
2.07  | 2.78  | 4.05  | 6.12  | 8.61  | 11.9  | 16.2  | 21.2  | ||||
规格  | 450  | 500  | 550  | 600  | 670  | 750  | 840  | 950  | 1070  | 备注  | 
减速器热功率Pt  | ||||||||||
SH TR型  | 49.7  | 61.4  | 74.3  | 88.4  | 110  | 138  | 173  | 222  | 281  | 见注1  | 
SHC TRC型  | 39.1  | 48.3  | 58.4  | 69.5  | 86.7  | 109  | 136  | 174  | 221  | i≤176.5  | 
31.9  | 39.4  | 47.6  | 56.7  | 70.7  | 88.6  | 111  | 142  | 180  | i≥200.1  | |
SHZ TRZ型  | 35.0  | 43.2  | 52.2  | 62.2  | 77.5  | 97.2  | 122  | 156  | 198  | i≤70.3  | 
31.6  | 39.1  | 47.3  | 56.2  | 70.1  | 87.9  | 110  | 141  | 179  | 77.9<i≤228.8  | |
26.8  | 33.1  | 40.1  | 47.7  | 59.4  | 74.5  | 93.4  | 119  | 152  | i≥259.3  | |
注:1.SH(TR)型的热功率应除以校正系数Ki=1+0.09(i-11);i为所选吃瓜91 传动比。
2.表中热功率为实验室条件下采用油池飞溅润滑的值,选用可根据环境的散热条件适当增减;或采用相应的冷却散热措施
3.其他吃瓜91 生产厂家生产的吃瓜91 的热功率,可参考表中相近的结构型式并根据其散热表面积的大小适当增减。
每小时运转周期10%  | 100  | 80  | 60  | 40  | 20  | 
运转周期系数Kw  | 1  | 0.94  | 0.86  | 0.74  | 0.56  | 
功率利用率%  | 80-100  | 70  | 60  | 5  | 40  | 
运转利用系数Kp  | 1  | 1.05  | 1.10  | 1.15  | 1.25  | 
功率利用率指P2/P1×100%.P2-实际负功率;
P1-额定许用功率(吃瓜91 所示功率)
                        
                    
            
       
                 







                            